Characterization of long pathlength capillary waveguides for evanescent chemical sensing applications

Research output: Contribution to journalConference articlepeer-review

4 Scopus citations

Abstract

Light-guiding fused silica capillary tubing has promising applications in the field of chemical sensors. Light propagation in these waveguides occurs within the fused silica capillary wall as opposed to liquid core waveguides where light traverses the solution-filled inner core. The electric field of light within the capillary wall extends slightly into the capillary inner diameter as an evanescent wave. An evaluation of the optical absorbance characteristics of these novel capillaries was performed by coupling the light source from a spectrophotometer into a capillary waveguide flow cell. A series of four thiacyanine dyes in methanol solution provided distinct absorbance peaks throughout the visible spectrum (400-800 nm). Evanescent absorbance values show a linear dependence upon capillary length up to ∼10 m (with 150 μm inner diameter). Evanescent absorbance measurements were nonlinear with solution concentration for all capillary lengths and may be attributed to adsorption of the ionic dye on the capillary fused silica inner surface. The waveguide effective pathlength ratio (EPLR) was determined by comparing evanescent absorbance values to conventional measurements in a 0.1 mm pathlength cuvette. The EPL is on the order of 10-5 - 10-6 m per meter of capillary tubing and also shows wavelength dependence. The evanescent field penetration depth ratios from experiment were dp ratio (424 nm) = 0.60 ± 0.07, dp ratio (557 nm) = 0.78 ± 0.10, and dp ratio (652 nm) = 0.73 ± 0.07 when normalized to d p ratio (758 nm) and compare reasonably with predicted values of 0.56, 0.73, 0.86, and 1.00 respectively. Absorbance sensitivity was investigated with 50, 150, and 250 μm inner diameter capillaries (360 μm outer diameter) that have theoretical inner reflection ratios of 1, 1.7, and 6.9 respectively. Experimentally measured ratios were 1, 2.0 ± 0.9, and 6.5 ± 1.2.

Original languageEnglish
Article number25
Pages (from-to)143-151
Number of pages9
JournalProceedings of SPIE - The International Society for Optical Engineering
Volume5585
DOIs
StatePublished - 2004
EventChemical and Biological Point Sensors for Homeland Disease II - Philadelphia, PA, United States
Duration: Oct 26 2004Oct 27 2004

Keywords

  • Attenuated total reflection spectroscopy
  • Capillary waveguides
  • Evanescent sensors
  • Evanescent wave absorbance spectroscopy

Fingerprint

Dive into the research topics of 'Characterization of long pathlength capillary waveguides for evanescent chemical sensing applications'. Together they form a unique fingerprint.

Cite this