T1 - The Effect of Footwear, Running Speed, and Location on the Validity of Two Commercially Available Inertial Measurement Units During Running
AU - Napier, Christopher
AU - Willy, Richard W.
AU - Hannigan, Brett C.
AU - McCann, Ryan
AU - Menon, Carlo
N1 - Publisher Copyright:
Copyright © 2021 Napier, Willy, Hannigan, McCann and Menon.
PY - 2021/4/26
Y1 - 2021/4/26
N2 - Introduction: Most running-related injuries are believed to be caused by abrupt changes in training load, compounded by biomechanical movement patterns. Wearable technology has made it possible for runners to quantify biomechanical loads (e.g., peak positive acceleration; PPA) using commercially available inertial measurement units (IMUs). However, few devices have established criterion validity. The aim of this study was to assess the validity of two commercially available IMUs during running. Secondary aims were to determine the effect of footwear, running speed, and IMU location on PPA. Materials and Methods: Healthy runners underwent a biomechanical running analysis on an instrumented treadmill. Participants ran at their preferred speed in three footwear conditions (neutral, minimalist, and maximalist), and at three speeds (preferred, +10%, −10%) in the neutral running shoes. Four IMUs were affixed at the distal tibia (IMeasureU-Tibia), shoelaces (RunScribe and IMeasureU-Shoe), and insole (Plantiga) of the right shoe. Pearson correlations were calculated for average vertical loading rate (AVLR) and PPA at each IMU location. Results: The AVLR had a high positive association with PPA (IMeasureU-Tibia) in the neutral and maximalist (r = 0.70–0.72; p ≤ 0.001) shoes and in all running speed conditions (r = 0.71–0.83; p ≤ 0.001), but low positive association in the minimalist (r = 0.47; p < 0.05) footwear condition. Conversely, the relationship between AVLR and PPA (Plantiga) was high in the minimalist (r = 0.75; p ≤ 0.001) condition and moderate in the neutral (r = 0.50; p < 0.05) and maximalist (r = 0.57; p < 0.01) footwear. The RunScribe metrics demonstrated low to moderate positive associations (r = 0.40–0.62; p < 0.05) with AVLR across most footwear and speed conditions. Discussion: Our findings indicate that the commercially available Plantiga IMU is comparable to a tibia-mounted IMU when acting as a surrogate for AVLR. However, these results vary between different levels of footwear and running speeds. The shoe-mounted RunScribe IMU exhibited slightly lower positive associations with AVLR. In general, the relationship with AVLR improved for the RunScribe sensor at slower speeds and improved for the Plantiga and tibia-mounted IMeasureU sensors at faster speeds.
AB - Introduction: Most running-related injuries are believed to be caused by abrupt changes in training load, compounded by biomechanical movement patterns. Wearable technology has made it possible for runners to quantify biomechanical loads (e.g., peak positive acceleration; PPA) using commercially available inertial measurement units (IMUs). However, few devices have established criterion validity. The aim of this study was to assess the validity of two commercially available IMUs during running. Secondary aims were to determine the effect of footwear, running speed, and IMU location on PPA. Materials and Methods: Healthy runners underwent a biomechanical running analysis on an instrumented treadmill. Participants ran at their preferred speed in three footwear conditions (neutral, minimalist, and maximalist), and at three speeds (preferred, +10%, −10%) in the neutral running shoes. Four IMUs were affixed at the distal tibia (IMeasureU-Tibia), shoelaces (RunScribe and IMeasureU-Shoe), and insole (Plantiga) of the right shoe. Pearson correlations were calculated for average vertical loading rate (AVLR) and PPA at each IMU location. Results: The AVLR had a high positive association with PPA (IMeasureU-Tibia) in the neutral and maximalist (r = 0.70–0.72; p ≤ 0.001) shoes and in all running speed conditions (r = 0.71–0.83; p ≤ 0.001), but low positive association in the minimalist (r = 0.47; p < 0.05) footwear condition. Conversely, the relationship between AVLR and PPA (Plantiga) was high in the minimalist (r = 0.75; p ≤ 0.001) condition and moderate in the neutral (r = 0.50; p < 0.05) and maximalist (r = 0.57; p < 0.01) footwear. The RunScribe metrics demonstrated low to moderate positive associations (r = 0.40–0.62; p < 0.05) with AVLR across most footwear and speed conditions. Discussion: Our findings indicate that the commercially available Plantiga IMU is comparable to a tibia-mounted IMU when acting as a surrogate for AVLR. However, these results vary between different levels of footwear and running speeds. The shoe-mounted RunScribe IMU exhibited slightly lower positive associations with AVLR. In general, the relationship with AVLR improved for the RunScribe sensor at slower speeds and improved for the Plantiga and tibia-mounted IMeasureU sensors at faster speeds.
KW - biomechanics
KW - footwear
KW - inertial measurement units
KW - running
KW - validity
UR - http://www.scopus.com/inward/record.url?scp=85122825998&partnerID=8YFLogxK
U2 - 10.3389/fspor.2021.643385
DO - 10.3389/fspor.2021.643385
M3 - Article
AN - SCOPUS:85122825998
SN - 2624-9367
VL - 3
JO - Frontiers in Sports and Active Living
JF - Frontiers in Sports and Active Living
M1 - 643385
ER -